POWER WORLD SIMULATOR FEATURES PDF MOD
POWER WORLD SIMULATOR FEATURES PDF GENERATOR
A 2D cell-based terrain generator that creates continent-based worlds with semi-realistic temperature, rainfall patterns, and drainage basins.The objective here is to start playing and start gaining some intuition.'Worlds' is a simulator intended to recreate human history all the way from its origins in alternate world settings. I do not expect you to “know” what is going on in a power flow case. Pose one or two explanations of what is happening in the system as you make these changes and as the system responds to your changes. State why the results are unexpected or non-intuitive. State what you did, perhaps with an annotated figure of the one-line diagram to aid your explanation. Find one (or two related) things to change on this system that lead to unexpected, or non-intuitive results. The real power generation/load is shown at each bus, while the per unit reactance of each of the lines (on a 100MVA base) is shown in yellow.

What is the significance of the reactive power output of a generator, to the owner of the generator? … to the power system? (very brief comments) (Note: To change the generator 2 voltage set point first select Tools, Play to begin the power flow simulation and then click on the up/down arrows on the bus 2 magenta voltage set point field.) 3. Plot the reactive power output of the generator at Bus 2 as a function of its voltage set point value in 0.005 pu voltage steps over the range between its lower limit of -50MVAr and its upper limit of +50MVAr. Load PowerWorld Simulator case Problem 6_46. Briefly comment on the meaning and/or significance of these losses and interpret your plot.

Plot the real and reactive line losses as Qcap is varied between 0 and 10.0 MVArs. Why would a consumer be interested in the results of (a) and/or (b) above? (very brief comment) e. Why would a power company be interested in the results of (a) and/or (b) above? (very brief comment) d. State what “MVA power flow into the feeder” actually is. State/show how you determine the MVA power flow into the feeder. Include a screen shot of the PowerWorld one-line diagram for this value of Qcap. What value of Qcap minimizes the MVA power flow into the feeder? i. State/show how you determine the real power line losses. What value of Qcap minimizes the real power line losses? i. The load is compensated with a capacitor whose output, Qcap, can be varied in 0.5 MVAr steps between 0 and 10.0 MVArs. This system has an 8 MW/4 MVAr load that is supplied at 13.8 kV through a feeder with an impedance of 1 + j2Ω. Open Problem 2_32 (in chapter 2 of the GSSampleCases folder, in the Simulator folder).

Using the PowerWorld Simulator, do the following three problems.